Transformer Rectifiers (Air Cooled / Oil Cooled)
The most basic type of cooling system is an oil-cooled transformer rectifier, which uses the oil’s natural convection flow to lessen the temperature differential between the transformer and the surrounding air.
An automatic controlled transformer known as an air-cooled transformer rectifier provides the DC power needed for impressive current cathodic protection. Because of its lightweight design and compact structure, it is perfect for smaller installations in cleaner settings.
Transformer Rectifiers (Air Cooled / Oil Cooled):
- Input: 220-240 V ac/ 380 V ac, Or Dual Input.
- Output: To suit application, please request DC Voltage and Amperage as required.
- Cooling: ONAN (oil immersed, natural convection air cooled).
- Control: Manual Thyristor Control, VARIAC Control & Automatic Control.
- Enclosure: The oil tank is constructed from 2 or 3mm (depending on size) thick mild steel sheet. The oil tank is formed into shape and will be fully on outside seams. Moreover, it can be Manufactured as Carbon Steel Coated, Stainless Steel.
- Optional: Remote Monitoring Systems, Software interface, GPS timer interrupter, RS485 Telemetry, auto potential control, Removable sunshade, and More features are available on request
- Classification: Safe Area / Hazardous Area.
Related Products
Impressed Current Anodes
Impressed Current Anodes One type of anode used in cathodic protection systems is called an impressed current anod
Welding Machines
Welding Machines The Spot Welding Kit, which enables rapid and simple connections between the MMO/Ti Ribbon anode
Junction Boxes
Junction Boxes Applications involving cathodic protection employ junction boxes. For Junction Boxes with Post and
Carbonaceous Backfill
Carbonaceous Backfill (Metallurgical) Our backfill is of the highest caliber, which is crucial for boosting CP Sys
Test Point
Test Point (Test Stations) Utilized in situations involving road crossings and cathodic protection monitoring. It
Insulating joints
Insulating joints We provide linear expansion joints, PE steel transitions, and monolithic insulating joints. The
Electronic Decoupling Devices (PCR)
Electronic Decoupling Devices (PCR) EDD designed as a polarization cell replacement (PCR). The EDD is a solid-stat
Permanent Reference Electrode
Permanent Reference Electrode used to measure Cathodic Protection (CP) Potentials on buried pipelines, storage tan
Portable Reference electrode
Portable Reference electrode Intended to be used in loose soils. According to the kind of soil, we can use either
ICAF / MGPS
ICAF / MGPS Utilized to cost-effectively prevent biofouling of interior pipework and strainers in cooling systems
Transformer Rectifiers
Transformer Rectifiers (Air Cooled / Oil Cooled) The most basic type of cooling system is an oil-cooled transforme
Solar Energy
Solar Energy The DC Output, battery bank autonomy, and location specifications supplied by the customer are taken